MAKE AN ENQUIRY

Type 133 Load Cell Amplifier

The Type 133 Load Cell Amplifier enables a customer to be able to configure and amplify analogue outputs to several combinations based input ranges and on Current or Voltage outputs.

Type 133 Load Cell Amplifier

Our 133 Strain gauge load cell amplifier gives the ability to easily and simply configure analogue outputs to your Current (mA) or Voltage (VDC) output requirement.

  • Bridge Resistance:  120 – 2,000 Ω
  • Load Cell Connection: 4 wire
  • Power Supply: 12V – 24V
  • Operating Temperature: – 20ºC to 50ºC
  • Bridge Excitation Voltage: 8.0 V DC
  • Linearity: 1:4,000
  • Bipolar Output
  • RoHS compliant

Firstly, the Type 133 Load Cell Amplifier’s basic function is to amplify the signal from any load cell with full bridge connection.

Amplifying this signal allows the user to use the data from the load cell in a more efficient and productive way.

Secondly, the amplifier is housed in an ABS enclosure allowing easy installation or mounting to a suitable surface with a single screw.

Type 133 Load Cell Strain Gauge Amplifier Specification

PRODUCT FULL SCALE INPUT RANGE

Model Prefix ‘Type 133’ followed by…

  • (A)      0.25mV/V – 0.85mV/V
  • (B)      0.65mV/V – 1.65mV/V
  • (C)       1.5mV/V – 2.5mV/V
  •  (D)     2.25mV/V – 3.25mV/V

 

PRODUCT OUTPUT TYPE
  • 4-20 mA
  • 12mA +/-8 mA
  • 0-10 V
  • 5V +/- 5V

This means you can have one amplifier with multiple configurations available for you enabling changes and setups to be achieved, quickly, simply and effectively.

Contact Team

      Type 133 Load Cell Amplifier Datasheet

      CART

      CONTACT

      • Datum HQ Headquarters
      • Castle Street
      • East Cowes
      • United Kingdom
      • PO32 6EZ
      • +44 (0) 1983 28 28 34
      • web@datum-electronics.co.uk

      DOWNLOADS

      Type 133 Load Cell Amplifier Datasheet

      BENEFITS

      Powered by DATUM ELECTRONICS